E-line

by DIRAK DIRAK GmbH • Königsfelder Straße 1 • 58256 Ennepetal/Germany • Phone: +49 (0) 2333 / 837-0 • Fax: +49 (0) 2333 / 837-103 PI Item Number 910-0590.02 Product Information 150e v2.1 With MLU5000 Locks, you can secure those decentralised server cabinets, where it may not be possible to use the MLR5000 with adapters for your particular cam, rod or offset latching system. The MLU5000s are also well suited as additional latches on very high doors by connecting an additional MLU1000 to the card reader. An emergency power option is available as a Battery Pack accessory, which allows the MLU5000s to be opened in the event of a power failure. The MLU5000 Locks are supplied as a set together with the MLU1000, MLU Reader and Network Reader Unit. MLU5000 Technical Specifications Three-part hardware system MLU5000 Set Set consists of: external MLU Reader; Network Reader Unit and MLU1000 Lock Indicators on MLU Reader 2 x multicolor status LEDs and 1x backlit information field Antenna For 125 kHz transponder (HID 26-bit system) MLU1000 Lock Material Die-cast zinc Color Chrome matte Control cable length 4 m Supply voltage, current 24 V DC +/- 10 % 100 mA Status contact Proximity switch Thickness of mounting wall/sheet metal No restrictions Opened electronically by: Interrupting power MLU5000 Network Reader Housing Reader unit in plastic housing, mountable with screws or self-adhesive pad Nominal input voltage 12/24/48 V ± 10% (DC); depends on connected electr. lock Standby current (system ready) 40 mA (DC) Maximum current on RJ12 (LOCK) 1,5 A (DC) Maximum current on relay terminals 3.0 A (DC), terminals 10-11 RS-232 interface RS-232 lines (RXD ,TXD, GND, Reader present, PC present), 38,400 Baud Connection cable (Reader -> external MLU antenna) 8-pin; 350 cm; UL-approved, 26 AWG stranded wire; RJ45 connector molded onto one end; crimped JST ZHR-8 connector on other end Relay output (screw terminals) 2,5 mm², screw on insertion side; Relay contact: 12 V, 3 A, 60 W, 120 VA, terminals 3-5 Door contact input (screw terminals) 2.5 mm², screw on insertion side, terminals 1 and 2 TCP/IP interface Ethernet, 10100 autosense, up to 100 Mbit/s Open or closed when power interrupted This is configured in the Administration Suite Config-Tool depending on connected electr. lock Storage capacity for transponder cards 2,000 cards + 1 master transponder Storage capacity for events 500 events (ring buffer) Storage capacity for time profiles 30 profiles Integrated real-time clock With buffering for up to 60 min. at 25°C Temperature range -20°C ... +70°C

RkJQdWJsaXNoZXIy MzU3MDg=